| DC INVERTER | JAUS-09H53GVC1-710(BpRD6) | JAUS-12H53GVC1-730(BpRD6) | JAUS-18H53GVG1-850A(BpRD6) | ||
| Rated Power supply | 1Ph / 220-240V/50Hz | 1Ph / 220-240V/50Hz | 1Ph / 220-240V/50Hz | ||
| Workable Power supply | 1Ph / 150-260V/50Hz | 1Ph / 150-260V/50Hz | 1Ph / 150-260V/50Hz | ||
| Cooling | Capacity (btu/h) | 9000 | 12000 | 18000 | |
| Capacity (W) | 2600(150~3200)W | 3300(150~3900)W | 5300(1200-6200) | ||
| Input (W) | 630(60~1100)W | 800(60~1400)W | 1250(120-1700) | ||
| Rated current (A) | 2.8 (0.3~4.9)A | 3.6(0.3~6.3)A | 5.6(1.3~7.5) | ||
| Pdesign (W) | 2600 | 3300 | 5200 | ||
| SEER | 8.50 | 8.50 | 9.35 | ||
| Heating | Capacity (btu/h) | 9000 | 12000 | 18000 | |
| Capacity (W) | 2800(150~3800)W | 3500(150~4500)W | 5800(1250-6600) | ||
| Input (W) | 730(60~1100)W | 900(60~1400)W | 1500(160-1850) | ||
| Rated current (A) | 3.3(0.3~4.9) | 4.0(0.3~6.3)A | 6.6(1.5~8.2) | ||
| Pdesign (W) | 2450 | 2550 | 4550 | ||
| SCOP | 4.60 | 4.60 | 4.8 | ||
| Max. input consumption (W) | 1600 | 1720 | 2400 | ||
| Max. current (A) | 8.00 | 9.00 | 11.00 | ||
| Compressor | Brand | GMCC | GMCC | GMCC | |
| Type | Rotary | Rotary | Rotary | ||
| Indoor unit | Indoor Coil | Fin material | Golden& hydrophilic | Golden& hydrophilic | Golden& hydrophilic |
| Tube outside dia.and material | φ5mm, inner Grooved | φ7mm, inner Grooved | φ7mm, inner Grooved | ||
| Indoor air flow (Turbo/Hi/Mi/Lo) (M3/h) | 600/500/450/400 | 650/550/500/450 | 1050/950/800/680 | ||
| Rated input Power(cooling/heating) (W) | 30 | 30 | 35 | ||
| Rated current (cooling/heating) (A) | 0.2 | 0.2 | 0.35 | ||
| Moisture Removal (KG/h) | 1.2 | 1.2 | 1.8 | ||
| Noise level(Turbo/Hi/Mi/Lo) (dB(A)) | 42/39/36/33 | 42/39/36/33 | 47/44/41/39 | ||
| Unit dimension (W*H*D) | 810×295×205 | 810×295×205 | 955x335x230 | ||
| Packing (W*H*D) | 875×340×255 | 875×340×255 | 1020×400×300 | ||
| Net weight (KGs) | 8 | 8 | 12 | ||
| Gross weight (KGs) | 10 | 10 | 14 | ||
| Outdoor unit | Outdoor coil | Fin material | Golden& hydrophilic | Golden& hydrophilic | Golden& hydrophilic |
| Tube outside dia.and material | φ7mm, Inner Grooved | φ7mm, Inner Grooved | φ7mm, Inner Grooved | ||
| Noise level (dB) | 50 | 52 | 55 | ||
| Unit dimension (W*H*D) (mm) | 780(710)×295×495 | 800(730)×305×550 | 910(850)×385×700 | ||
| Packing (W*H*D) (mm) | 818×328×530 | 835×340×580 | 960×420×744 | ||
| Net weight (KGs) | 23 | 23.5 | 38 | ||
| Gross weight (KGs) | 26 | 26.5 | 42 | ||
| Refrigerant type | R32 | R32 | R32 | ||
| Refrigerant pipe | Liquid side (mm) | Φ6 | Φ6 | Φ6 | |
| Gas side (mm) | Φ9 | Φ9 | Φ12 | ||
| Max. refrigerant pipe length (m) | 10 | 10 | 10 | ||
| Max. difference in level (m) | 5 | 5 | 5 | ||
| Operation temperature range | -7℃-43℃ | -7℃-43℃ | -7℃-43℃ | ||
| Ambient temperature range | -15℃-48℃ | -15℃-48℃ | -15℃-48℃ | ||
| Application area (MM2) | 10~17 | 13~27 | 20~40 | ||
| Sets per 40ft HQ/20ft | 308 /- | 286/124 | 160 / - | ||
In a world where technological advancements dictate the pace of progress, the demand for climate control solutions has surged. Air conditioning, particularly in data centers, has become a necessity. Why? Because without proper cooling, servers can overheat, leading to catastrophic failures. The market for China factory data center Air Conditioners is booming.
The Landscape of Data Center Cooling Solutions
Consider this: in 2022, the global data center cooling market was valued at approximately $10 billion. By 2028, it’s projected to exceed $20 billion. Impressive, right? The growth is driven by the increasing need for efficient cooling systems that can handle the heat generated by densely packed servers.
Key Players in the Market
- Pazoeoeic
- Schneider Electric
- Vertiv
- Stulz
Each of these brands brings something unique to the table. For instance, Pazoeoeic has been blending innovation with affordability, making their products sought after for wholesale purchases.
Types of Air Conditioners Used in Data Centers
When selecting an air conditioning system for a data center, several options come into play:
- In-row cooling units
- Chilled water systems
- Direct expansion systems
Each type has its advantages and challenges. In-row cooling units, for instance, can deliver precise cooling right where it’s needed, while chilled water systems are often more energy-efficient. Yet, do we really consider the long-term operational costs? It’s not just about initial investments.
Energy Efficiency and Sustainability
Energy efficiency is crucial. Data centers consume nearly 2% of the world's energy supply, and this figure is rising. Implementing energy-efficient cooling solutions not only cuts costs but also reduces carbon footprints. A case in point: a major cloud provider recently transitioned to Pazoeoeic’s eco-friendly air conditioning units, resulting in a 30% reduction in energy costs.
The B2B Wholesale Model
Wholesale purchasing offers significant savings. For businesses, buying Air Conditioners in bulk can lead to discounts and better terms. When procuring from Chinese manufacturers, factors like shipping times, tariffs, and reliability come into play. Look at the logistics: a shipment of 100 units can arrive in a matter of weeks, but if a buyer isn't prepared, delays can occur.
Choosing the Right Supplier
Not all suppliers are created equal. A diligent buyer should consider:
- Supplier reputation
- Product certifications
- Customer support
Imagine a scenario where a company orders a batch of air conditioners only to find they don’t meet regulatory standards. Ouch! That’s a nightmare.
Future Trends in Data Center Cooling
As we look ahead, several trends are emerging that could redefine the landscape of data center cooling:
- Integration of AI for predictive cooling
- Use of renewable energy sources
- Advanced monitoring systems
Can you believe that AI could optimize cooling efficiency by predicting server loads? It’s game-changing. Companies that adapt will thrive.
Conclusion
In the realm of data center air conditioning, B2B wholesale offers a plethora of opportunities. With the right supplier, like Pazoeoeic, businesses can secure cooling solutions that not only meet their current needs but also anticipate future demands. The future of cooling is not just about maintaining temperature; it's about enhancing operational efficiency and sustainability.